Actuator/Cable Replacement
1. Disconnect the 4-P connector from the actuator.Actuator Cable Replacement:
2. Remove the two mounting bolts and the actuator with the bracket.
3. Remove the EVAP purge control solenoid valve from the actuator bracket.
4. Remove the vacuum hose.
5. Remove the three nuts.
Actuator Cable Replacement:
6. Disconnect the actuator cable from the actuator rod by releasing the clip from the rod with a screwdriver as shown.
Actuator Cable Replacement:
7. Loosen the locknut, then disconnect the actuator cable from the throttle linkage.
8. Install in the reverse order of removal, and adjust free play at the throttle linkage after connecting the actuator cable.