Battery - Required Diagnostic Routine
Bulletin # P88-016Section: Product
Dated: 12/05/88
Subject:
BATTERY DIAGNOSIS
To: ALL RANGE ROVER DEALERS
Recent warranty statistics show an increase in battery replacements. We need your help to learn more about the situation. The attached Battery/Charging System Check Procedure should be used before replacing a battery.
In order to properly check the battery and charging system, you will need the following:
^ Temperature compensated battery hydrometer
^ SUN VAT 40 (or equivalent) charging/starting system tester
Please contact Jim Davis at 1-800-622-0266 whenever a battery replacement is needed. Alternatively, send a Product Report marked "Battery Survey".
BATTERY TEST PROCEDURE
^ Inspect battery for low electrolyte level, corroded or loose terminals and case leakage.
Replace if: Case is damaged or terminal posts are loose
Correct: Low electrolyte level with distilled water Clean terminals if required
^ Test each cell with a temperature corrected hydrometer.
Replace if: Cells vary 0.050 or more (Highest to Lowest)
Recharge if: Specific gravity is less than 1.260
^ Load test battery at 210 amps for 15 seconds (specific gravity at least 1.260).
Replace if: Voltage is less than 9.6 after 15 seconds
If battery needs replacement or is found low on charge, perform a Charging System Check/Alternator Test Please follow steps 1-10 in the Workshop Manual, Section 86, page 11.
Please call Jim Davis at 1-800-622-0266 to report any battery failures, or submit a Product Report marked "Battery Survey".