Ignition Coil: Testing and Inspection
TESTING OF IGNITION COIL
1. Measurement of the primary coil.
Measure the resistance between the positive terminal and negative terminal of the ignition coil.
Standard value: Approx. 1.0 ohm
2. Measurement of the secondary coil resistance.
Measure the resistance between the ignition coil's positive terminal and the high-voltage terminal.
Standard value: Approx 10.0 - 14.0 kohm