Subframe Bolts - New Tightening Procedure
85VW1Applies To QUANTUM
1985
Group
40
Subject
Subframe
Part Identifier N/A
Key Points
New tightening procedure for subframe bolts
A160
Number
85-04
September 9, 1985
The tightening procedure for the subframe bolts has been changed.
Previous procedure: torque to 70 N-m (52 ft.lbs.)
New procedure: torque to 35 N-m (28 ft..lbs.) plus 1/4 turn (90~)
CAUTION
ALWAYS replace bolts and flat washers at each repair.
Contact surfaces of bolts and washers must be free of grease and wax.